Numéro |
2013
16th International Congress of Metrology
|
|
---|---|---|
Numéro d'article | 02001 | |
Nombre de pages | 5 | |
Section | Débitmétrie industrielle / Industrial flow measurement | |
DOI | https://doi.org/10.1051/metrology/201302001 | |
Publié en ligne | 7 octobre 2013 |
Numerical analysis of the discharge coefficient with disturbers for flowmetring accuracy
1 FIMA Laboratory, University of Khemis Miliana, Route de Theniet El Had, Algeria
2 Mechanical department, University of Sciences and Technology Oran, Bir El Djir, Algeria
The present work concerns a numerical investigation of the effect of orifice meter diameters on the discharge coefficient for flow measurement purpose. The flow is subject to two disturbers namely a 90° double bend in perpendicular planes and a 50% closed valve. The turbulent flow is examined in conduit with an inner diameter of D=100mm. The diameter of orifice meters are respectively d=40, 50, 60, 70 and 75mm which done for β ratio d/D respectively the values of 0.4, 0.5, 0.6, 0.7 and 0.75. The orifice meters are located in conduit at different stations downstream the disturbers. The flow is examined with air at Reynolds number Re=2.5x105. The software used for this simulation is CFD code Fluent with k-ε like turbulence model. As a conclusion, the analysis of numerical results shows that when the diameter of the orifice meter increases the shifts deviation in the discharge coefficient increases this causes a great error in flow measurement. Contrary, when the diameter of the orifice meter decreases the shifts deviation in the discharge coefficient decreases and the errors in flow measurement is reduced. These results are the same with the two disturbers used separately in conduit.
© Owned by the authors, published by EDP Sciences, 2013
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 2.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.