Open Access
Issue
2019
19th International Congress of Metrology
Article Number 19005
Number of page(s) 21
Section Biology - Health / Biologie-Santé
DOI https://doi.org/10.1051/metrology/201919005
Published online 23 September 2019
  • RR. Davis: Measurement of pedal loading in bicycling: I. Instrumentation. J Biomech; 412:843-56 [1981]. [Google Scholar]
  • ML. Hull, C. Sone Rider/&bicycle Interaction Loads During Standing Treadmill Cycling. J Biomech; 9:202-218 [1993] [Google Scholar]
  • F. Woods, G & Day, L & T Withers, R & H Ilsley, A & F Maxwell, B. The Dynamic Calibration of Cycle Ergometers. International journal of sports medicine. 15. 168-71. 10.1055/s-2007-1021041 [(1994).]. [CrossRef] [PubMed] [Google Scholar]
  • Gurgel, Jonas & Porto, Flavia & Russomano, Thais & Cambraia, Rodrigo & Azevedo, Dario & Glock, F.s & Carlos Pinheiro Beck, João & Helegda, Sergio. (2006). Development and Calibration of a Pedal with Force and Moment Sensors. Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference. 1. 4144-6. 10.1109/IEMBS.2006.260719. [Google Scholar]
  • Stapelfeldt, Björn & Mornieux, Guillaume & Oberheim, R & Belli, Alain & Gollhofer, Albert. Development and Evaluation of a New Bicycle Instrument for Measurements of Pedal Forces and Power Output in Cycling. International journal of sports medicine. 28. 326-32. 10.1055/s-2006-924352 [2007]. [CrossRef] [PubMed] [Google Scholar]
  • Mimmi, Giovanni & Rottenbacher, Carlo & Bonandrini, Giovanni. (2007). Pedalling Strength Analysis in Pathological and Non-pathological Subjects on Cycle-ergometer Instrumented with Three-components Pedals. 18-21. [Google Scholar]
  • Vanwalleghem, Joachim & Mortier, Frederik & De Baere, Ives & Loccufier, Mia & Van Paepegem, Wim. Design of an instrumented bicycle for the evaluation of bicycle dynamics and its relation with the cyclist’s comfort. Procedia Engineering. 34. 485–490. 10.1016/j.proeng.2012.04.083 [2012]. [Google Scholar]
  • Balbinot, A & Milani, Cleiton & Nascimento, Jussan. A New Crank Arm-Based Load Cell for the 3D Analysis of the Force Applied by a Cyclist. Sensors (Basel, Switzerland). 14. 22921-22939. 10.3390/s141222921 [2014]. [CrossRef] [PubMed] [Google Scholar]
  • V. Omar, D. Rafael, C. Vinicius and B. Alexandre, “Complete factorial design experiment for 3D load cell instrumented crank validation,” 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, 2015, pp. 3655-3658. 10.1109/EMBC.2015.7319185 [2015]. [Google Scholar]
  • I. Kraemer, Luke & D. Gutierrez-Franco, Juan & E. Deschamps, Jake & C. Dudum, Karim & Dandekar, Eshan & Hazelwood, Scott & V. Porumamilla, Hemanth & M. Klisch, Stephen. Design and implementation of an instrumented pedal for cycling biomechanics research [2015]. [Google Scholar]
  • Bibbo, Daniele & Gabriele, Stefano & Scorza, Andrea & Schmid, Maurizio & Sciuto, Salvatore & Conforto, Silvia. Strain gauges position optimization in designing custom load cells for sport gesture analysis. 1-6. 10.1109/HealthCom.2018.8531106 [2018]. [Google Scholar]
  • Bibbo, Daniele & Gabriele, Stefano & Scorza, Andrea & Schmid, Maurizio & Sciuto, Salvatore & Conforto, Silvia. A Novel Technique to Design and Optimize Performances of Custom Load Cells for Sport Gesture Analysis. IRBM. 10.1016/j.irbm.2019.05.005 [2019]. [Google Scholar]