Issue |
2013
16th International Congress of Metrology
|
|
---|---|---|
Article Number | 06011 | |
Number of page(s) | 5 | |
Section | Les avancées en mesure 3D et Dimensionnel / Advanced coordinate metrology & Dimensional | |
DOI | https://doi.org/10.1051/metrology/201306011 | |
Published online | 07 October 2013 |
National comparison on verification of fuel dispensers
IPQ - Instituto Português da Qualidade, Rua António Gião, 2,, 2829-513, Caparica, Portugal
a Corresponding author: alameida@ipq.pt
In order to check the agreement of results and procedures in the field of verification of fuel dispensers by the verification bodies designated by the Portuguese Institute for Quality (IPQ), a national comparison between these entities was performed for the first time. A correction for reference temperature was performed to the results presented by the participants, maximum flow at 20 L and minimum flow at 5 L, using petrol and diesel as verification liquid. The analysis of the results, using the normalized error statistics, evidenced satisfactory values, for the majority of the national entities. The uncertainty components and values were very similar within the participants for the minimum flow at 5 L. For higher volume, the uncertainties were very dependent on the type of volume standard used.
© Owned by the authors, published by EDP Sciences, 2013
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 2.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.